Performance
Qualification of Ampoule/Vial Washing Machine
|
The ampoule/
vial washer is used to clean the drug container to eliminate the contamination
(endotoxin, chemical substance, particles etc.) from the container itself to
ensure that the products produced meet expectations for purity, identity,
safety, and quality.
Performance
of the ampoule/ vial washer should be qualified at regular intervals. Even though
depyrogenation may be achieved using a heating tunnel or oven, if the washing
process cannot remove chemical contaminants or particles, they will produce a
pyretic response in humans or animals, although there are no pyrogens present.
Thus decontamination studies for endotoxin,
chemical contaminants, and particles should be performed. Each study to
be challenged three times to verify the reproducibility of the machine’s
performance.
Endotoxin Decontamination Study
Inoculate
endotoxin suspension in each testing ampoule/vial ( 10 Numbers) calculated to obtain 100EU/ml. Dry in a oven
at 450C - 600C and 30 mmHg about one hour until no visual
water present. After drying send the spiked ampoule/vials for washing. After
washing send the ampoule/vials to Microbiology lab for testing
Acceptance
Criteria: at minimum, a three-log reduction in endotoxin.
Chemical Decontamination Study (Sodium
Chloride Challenge Test – [Soluble])
Prepare 30% Sodium chloride solution & spike
it in 10 ampoules/vials. Dry the ampoules/vials under LAF for 8-10 hours, after
drying send the
spiked ampoule/vials for washing. After washing send the vials to Quality
control lab for testing.
Acceptance
Criteria: Precipitation & chloride content should be absent in the
ampoules/vials after washing.
Particulate Decontamination Study (White Powder
Talc Solution Challenge Test – [In soluble])
Prepare white powder talc solution & spike
it in 10 ampoules/vials. Dry the ampoules/vials under LAF for 8-10 hours, after
drying send the
spiked ampoule/vials for washing. After washing send the vials to Quality
control lab for testing.
Acceptance
Criteria: 10 µ
particles NMT 25 & 25 µ particles NMT 3
Glass Particle Challenge Test
Take glass
particles and put it in 10 ampoules/vials. After washing
check visually for any glass particles.
Acceptance
Criteria: No
particles shall be observed in the ampoules/Vials after washing.
Note: For each study, the quantity of ampoules/vials
to be washed is the same as normal production size to demonstrate the
performance of the normal process.
This comment has been removed by a blog administrator.
ReplyDeleteThis comment has been removed by the author.
ReplyDeleteHi Don,
ReplyDeleteI'm validation analist and I found your article very interesting.
Please, could you say me what's the bibliographic reference did you use?
Thanks!
hi which references did you take ?
ReplyDeleteplease share me that article at ram06215@gmail.com.
ReplyDeleteThanks & regards
Ram Narayan
+91-9913915660
Ram which article you want?
Deleteplease share which references you used at ducpham61090@gmail.com
ReplyDeleteIt's very useful writing for new Co mmer
ReplyDeleteVery nice article
ReplyDeletewhich guidelines are you followed
ReplyDeleteWhy using Nacl solution for chemical challenge test ...
ReplyDeleteAny rational
please send me reference to refaat.harby@evapharma.com
ReplyDeletemany test are missing
ReplyDeleteAny rational for different vial size
ReplyDeletePlease share reference
ReplyDeletegood for knowledge. please refer any guideline for validation of dryheat sterilizer.
ReplyDeleteReference guidelines
ReplyDeleteThanks for sharing such wonderful stuff. Keep sharing and keep up the good work.
ReplyDeleteBest Job Portal
ReplyDeleteThat supposed to be the question of thousands.Here you have explained it beautifully. There is always a way to sort this out.Thanks for taking time out to publish this blog for everyone's benefit.
Diwali Wishes in Hindi
Diwali Wishes in Hindi Font
One of the best Article
ReplyDeleteVisit This Website: DOwnload Latest Movies
Visit This Website: DOwnload Latest Movies
Visit This Website: DOwnload Latest Movies
Visit This Website: DOwnload Latest Movies
Visit This Website: DOwnload Latest Movies
Visit This Website: DOwnload Latest Movies
Visit This Website: DOwnload Latest Movies
Good Blog, Such a Nice Content, Informative for Readers Keep Posting.
ReplyDeleteAlso checkout our website for best hospital management software in India.
Who we are?
Mednet Labs is the Best Hospital Software in India & one of the satisfactory software for the clinic control system in India. it's miles a secure platform for clinics and hospitals. It fulfils all the scientific necessities from coping with appointments to bills, all in one vicinity.
Best Hospital Management Software in India
Best Hospital Software in India
What is popular on prime? 2022 Popular Movies
ReplyDelete