Sunday 2 February 2020

Stability Testing Question & Answers –Antimicrobial Effectiveness Testing (AET) Requirements



The antimicrobial effectiveness test (previously known as the preservative effectiveness test),is a compendial test (antimicrobial test is described in USP <51>) performed during formulation development and stability testing of sterile parenteral multi-dose presentations of drug products that contain a preservative system.This test is intended to reproducible biological measurement of the activity of the preservative system in a product.  

The compendial AET tests of the USP and the European Pharmacopeia have very similar methods, but they differ in sampling points and acceptance criteria. 

How many batches shall be subjected for AET testing during stability study?

1.According to “USFDA Guidance for industry ANDAs: Stability Testing of Drug Substances and Products - Questions and Answers”

"One of the primary batches of the drug product should be tested for antimicrobial preservative effectiveness (in addition to preservative content) at the end of the proposed shelf life. The drug product specification should include a test for preservative content, and this attribute should be tested in all stability studies".



No comments: